- Home
- Pool heating
- TurboSilence Inverter Pool Heat Pump 26 kW - UniverT
TurboSilence Inverter Pool Heat Pump 26 kW - UniverT
TurboSilence Inverter 26kW Pool Heat Pump, heat your pool silently and with less energy consumption than with a conventional pump. Description détaillée
- TurboSilence Technology 10 times quieter
- Fast heating up to 120% capacity
- Intuitive touchscreen control
Low stock
Livraison offerte dès 150€
Paiement sécurisé
NEED HELP? Tel: +33.7.67.08.97.83
-
French company
-
Eco-friendly products
-
We'll support you
-
Easy to use
Heat large volumes with peace of mind. The TurboSilence Inverter 26 kW heat pump combines exceptional power and state-of-the-art technology to offer unparalleled swimming comfort for pools up to 120 m³.
Highlights of the 26 kW model
- Power for large pools: ideal for pools from 75 to 120 m³.
- Turbo 120% Mode: releases 25.5 kW of power for ultra-fast initial heating or temperature recovery.
- Record Coefficient of Performance (COP): up to 16.0 (at 20% capacity), certified by TÜV Rheinland.
- Absolute Silence: only 20.8 dB(A) at 10m in maintenance mode, a feat for a heat pump of this power.
- Integrated Connectivity: remote management via Wi-Fi for total control from your smartphone.
Why choose TurboSilence Inverter technology?
Unlike conventional Inverter systems, TurboSilence control dynamically balances compressor power and heat exchange. The result? You benefit from ultra-fast temperature rise without the usual noise pollution.
- 10 times quieter: where a standard heat pump emits around 59.1 dB(A), the 26 kW model drops to 49.2 dB(A) at full power. In maintenance mode, the noise becomes negligible.
- Zero vibration: it's the only technology on the market capable of completely eliminating compressor friction noise.
Demonstration of a Full-Inverter
Thanks to its advanced technology, this pump boasts an average COP of 11.5 (at 50% capacity) and can reach a COP of 16 (at 20% capacity), under optimal conditions (Air 26°C / Water 26°C / Humidity 80%). These performances are certified by TÜV Rheinland.
The principle of energy savings (over a 180-day season)
- The first 5 days: the pump operates at 100% capacity to quickly reach the set temperature.
- The next 175 days: the heat pump runs at an average of 50% of its power to maintain the water temperature. With an average COP of 11.5, it consumes half as much electricity as a classic "On/Off" pump.
Electricity consumption and silence
For comparison, for two 13.5 kW models (Full-Inverter vs On/Off) tested at 26°C, Inverter technology halves operating costs.
10 times quieter than a classic pump
By regulating its power to 50%, the sound pressure drastically drops. You benefit from a swimming environment 10 times quieter than with a traditional pump, with the noise becoming almost imperceptible once the temperature is stabilized.
UniverT Heat Pump Features
- Turbo Mode: rapid heating of the pool with 120% heating capacity, thanks to Turbo!
- Smart Mode: intelligent heating optimization based on ambient temperature and water temperature. Here's to energy savings.
- Silence Mode: night use with a heating capacity between 60% and 20%.
Different indicators on the UniverT pump screen

| SYMBOL | SYMBOL DESIGNATION | FUNCTION |
|---|---|---|
| ⏻ | ON/OFF | Power On / Off |
| 🔓 | Unlock | Press for 3 seconds to unlock / lock the screen |
| ⚙️ | Speed | Select Smart / Silence mode |
| ➕ ➖ |
Up / Down | Adjust programmed temperature |
The UniverT application


UniverT pump technical specifications
| Model | 11 kW | 13.8 kW | 17.5 kW | 21.5 kW |
|---|---|---|---|---|
| Recommended pool volume (m3) | 25 ~ 50 | 30 ~ 60 | 40 ~ 75 | 55 ~ 100 |
| Working air temperature (°C) | -15 ~ 43 | |||
| Performance conditions: air 26 ° C, water 26 ° C, humidity 80% | ||||
| Heating capacity (kW) in smart mode | 11 | 13.8 | 17.5 | 21.5 |
| Heating power (kW) in Turbo mode | 13.2 | 16.8 | 21 | 25.5 |
| COP in Smart mode | 8.2 | 7.5 | 7.3 | 7.8 |
| COP | 15.0 ~ 7.3 | 15.5 ~ 6.4 | 15.0 ~ 6.3 | 16.0 ~ 6.8 |
| COP at 50% speed | 11.6 | 11.2 | 11.2 | 11.3 |
| Performance conditions: Air 15 ° C, water 26 ° C, humidity 70% | ||||
| Heating power (kW) in Smart mode | 7.3 | 9.4 | 11.8 | 14.8 |
| Heating power (kW) in Turbo mode | 8.8 | 11.3 | 14.3 | 17.5 |
| COP in Smart mode | 5.3 | 5 | 5 | 5.4 |
| COP | 6.8 ~ 4.9 | 7.3 ~ 4.4 | 7.8 ~ 4.6 | 7.8 ~ 4.9 |
| COP at 50% speed | 6.5 | 6.6 | 6.8 | 6.8 |
| Sound pressure at 1m dB (A) | 38.6 ~ 46.9 | 42.0 ~ 47.7 | 42.9 ~ 50.8 | 40.8 ~ 51.2 |
| Sound pressure at 50% capacity at 1 m dB (A) | 41.3 | 43.7 | 44.5 | 44.4 |
| Sound pressure at 10 m dB (A) | 18.6 ~ 26.9 | 22.0 ~ 27.7 | 22.9 ~ 30.8 | 20.8 ~ 31.2 |
| Nominal input power (kW) at 15 ° C air | 0.22 ~ 1.8 | 0.26 ~ 2.56 | 0.31 ~ 3.08 | 0.38 ~ 3.53 |
| Recommended water flow (m³ / h) | 3 ~ 4 | 4 ~ 6 | 6.5 ~ 8.5 | 8 ~ 10 |
| Net dimensions LxWxH (mm) | 650 x 432 x 650 | 939 x 432 x 650 | 995 x 432 x 750 | 1125 x 429 x 952 |
| Net weight (kg) | 61 | 65 | 70 | 98 |
How to install a heat pump?
A heat pump is normally placed outdoors. It uses air for power, so it must have enough space around it to operate.
Here are some installation rules to follow:
- The heat pump must be placed on a stable, hard, and perfectly horizontal support.
- The distance between the pump and the pool must be at least 2 meters, and its front must be more than 50cm from any wall or barrier.
- It must be connected to a residual current circuit breaker.
- Even if the structures of heat pumps are resistant, it is imperative to protect it in winter with an adequate cover (provided).
| Model | TurboSilence Inverter 26 kW |
|---|---|
| Brand | UniverT |
| Type | Full-Inverter Pool Heat Pump |
| Recommended Pool Volume | 75 - 120 m³ |
| Technology | Full-Inverter + TurboSilence |
| Operating Air Temperature | -15°C to +43°C |
| Heating Power Smart Mode (Air 26°C / Water 26°C) | 13.8 kW |
| Heating Power Turbo Mode (120%) | 16.8 kW |
| COP Smart Mode (Air 26°C / Water 26°C) | 7.5 |
| Max COP | 15.5 |
| COP at 50% Capacity | 11.2 |
| Heating Power (Air 15°C / Water 26°C) | 9.4 kW (Smart) / 11.3 kW (Turbo) |
| COP (Air 15°C / Water 26°C) | 5.0 (Smart) / 7.3 - 4.4 |
| COP at 50% Capacity (Air 15°C) | 6.6 |
| Sound Pressure at 1m | 42.0 - 47.7 dB(A) |
| Sound Pressure at 50% Capacity (1m) | 43.7 dB(A) |
| Sound Pressure at 10m | 22.0 - 27.7 dB(A) |
| Absorbed Electrical Power (Air 15°C) | 0.26 - 2.56 kW |
| Recommended Water Flow | 4 - 6 m³/h |
| Power Supply | 230V single-phase |
| Dimensions (L x W x H) | 939 x 432 x 650 mm |
| Net Weight | 65 kg |
| Connectivity | Wi-Fi (smartphone control) |
| Available Modes | Turbo (120%), Smart (economical), Silence (night 20-60%) |
| Certification | TÜV Rheinland |
| Features | Touch screen, automatic defrost, anti-freeze protection |
| Contents | Heat pump + connection kit + cables + winter cover + manual |
| Warranty | 2 years |
Après le déballage, veuillez vérifier si vous disposez de tous les composants suivants : Pompe à chaleur TurboSlience, Kit d'installation raccords, Câbles électriques, Manuel d'utilisation

Shipping within 1 business day
Our packages are shipped daily via DPD, Colissimo, Chronopost, UPS, and DHL and are insured.
All orders placed before noon, Monday to Friday, are shipped the same day, and orders placed after noon are shipped the following business day.
Shipping costs
For mainland France, shipping costs are free for purchases over 150 euros. Below this amount, the delivery cost depends on the weight of your package and the carrier you select.
For international shipments, shipping costs can vary, depending on the destination and the cargo, from 4 euros to over 100 euros.
Returns
You can return your product within the 14-day withdrawal period upon receipt of your order by contacting customer service via email at contact@poolplanet.fr
Frequently Asked Questions about the UniverT Heat Pump
What is the difference between a Full-Inverter heat pump and an "On/Off" one?
Unlike a classic (On/Off) pump that always operates at 100%, the UniverT's Full-Inverter technology adjusts its power in real time. This means it consumes 50% less energy and is much quieter once the water temperature is stable.
Is the UniverT heat pump noisy?
Not at all. That's one of its strong points: it's 10 times quieter than a standard heat pump. In temperature maintenance mode, its sound pressure is so low that it becomes almost negligible, allowing you to enjoy your garden without any noise disturbance.
How does the 120% Turbo Mode work?
The Turbo Mode is designed for the beginning of the season or after a sudden drop in temperature. It boosts heating capacity to 120% to reach your ideal temperature in record time. Once the water is warm, the pump automatically switches back to economic mode.
Is power consumption really reduced?
Yes. Thanks to a high COP (Coefficient of Performance), for every 1 kW consumed, the pump delivers up to 11.5 kW of heat (at 50% of its capacity). On average, over a 180-day season, your operating costs are halved.
What are the advantages of the Night Silent Mode?
The Silent Mode reduces heating capacity by between 20% and 60%. This allows the water temperature to be maintained overnight with minimal electricity consumption and complete silence, thus respecting your sleep and that of your neighbors.
Why choose Pool Planet?
We select the best products for your pool and aim to help you find those that are truly right for you.
- Professional and recognized brands
- Inter-compatible products, designed to integrate seamlessly into your technical room without having to change everything
- Water, energy, and product savings thanks to "connected" technology.
- Decidedly human: from product selection to installation and after-sales service
Choosing Pool Planet means choosing a simpler, more durable, and better-equipped pool, with a French player established since 2008.
